SPC Innovative Solutions is a leading manufacturer of "Coolmaster"
repeater enclosures as well as outdoor equipment cabinets for
telecom, CATV and wireless applications.
|
|
SPC's ThermalPro 60 and 90 cabinets are designed to house
DSLAM electronics for providing broadband services. ThermalPro
60 is used in areas where less than 96 lines are required;
ThermalPro 90 brings capacity up to 144 lines. Either cabinet
can also be used for smaller fiber distribution applications.
Constructed from 1/10” aluminum for reduced weight and superior
corrosion ThermalPro 90 resistance and painted with a heat
resistant powder cost finish, these cabinets are compact
flexible units for applications where cabinet size and cost is a
concern.
With their innovative design, in DSL applications these cabinets
can be equipped with one DSLAM upon deployment to minimize first
cost and then as demand increases, craft friendly field upgrade
kits can be installed to increase capacity. Standard cooling
with substantial thermal margin is provided via a 48VDC fan/filter ventilation system.
These ThermalPro's are extremely flexible in terms of power;
they can house any 2U rectifier or DC to DC converter (if line
power is preferred) or simply act as an adjunct and manage power
from a host cabinet. The ThermalPro family of cabinets have been
tested to Telcordia GR 487 specifications and are NEMA4
compliant.
SPC's ThermalPro cabinets are designed specifically to house
electronics providing narrow and broadband services. The new
ThermalPro 120, 180, and 240 cabinets are offered as fully
integrated with power and electronics wiring or empty for
customer integration. ThermalPro's are constructed from 1/10”
aluminum with a rugged powder coat finish for reduced weight and
superior corrosion resistance. Both cabinets provide room for
future growth and heat exchangers or air conditioners are
provided as required. ThermalPro cabinets are designed to meet
Telcordia GR 487 Issue 2 specifications. |
 |
 |
|
The CoolMaster series of enclosures is the most thermally-capable and craft-friendly apparatus case found on the market
today. Available are three separate capabilities: CoolMaster
24 slot
16 slot
8 slot
CoolMaster is designed to hold 239 style single-wide repeater
cards for HDSL 2/4, HDSL, T1, ISDN or DDS networks. All models
are fully deployable, constructed from a specially formulated,
thermally efficient, corrosion resistant marine grade alloy,
designed to withstand the harshest environments. The CoolMaster
series is built for long-term, maintenance-free service, above
or below ground installation, and vented or pressurized
applications. SPC’s product focus is on highly engineered
outside plant enclosures with advanced thermal management
design. Consequently, SPC offers patented HDSL enclosures with
optimized heat dissipation to eliminate the need for tracking
repeater card fill levels and position. No need to skip
slots in these units!
|

|
 |
|
A totally self-contained and sealed, multi-environment
repeater for those times when an additional T1 circuit is needed
in a hurry. The SPC Encapsulated MiniPro™ T1 repeater is not
affected by moisture, corrosive atmosphere, heat or cold. The
compact size allows for simplified mounting on a pole, below
ground, in an existing pedestal, or splice case.
|
|
 |
|
The QuickPro™ weatherproof aluminum enclosure provides
protection and mounting for two single-wide HDSL cards or one
double-wide HDSL card. The enclosure incorporates an optimized
heat dissipating design ensuring circuit integrity while
providing a secure seal against moisture.
|
 |
 |
|
The CoolPro™ repeater enclosure is designed to withstand the
toughest outside plant environments. These stainless steel
enclosures provide long-term maintenance-free service in any
environment. The optimized heat dissipation design and slot
configuration allow full deployment of 4 or 8 single-wide
repeater cards for use in HDSL, T1, ISDN or DDS networks. The
seamless enclosure can be installed above or below ground and is
available in vented or pressurized models.
|

|
 |
|
Today's feature-rich and band width hungry applications
require fiber further out in the network. SPC's ThermalPro line
of Fiber Optic cabinets contain solutions for both active and
passive elements of your network.
The 432 Series is designed to receive up to 16 feeder fibers
from the CO or main fiber trunk line, split the signal and
distribute it to a maximum of 432 subscribers. The cabinet is
constructed of heavy gauge aluminum with a powder coat finish
for reduced weight and superior corrosion resistance. The top of
the cabinet is a double wall construction to reduce the effects
of solar radiation and for structural integrity. The end bay is
for cable entry, fiber splicing, and connection to the backside
of the distribution patch panels. There are 4 sealed cable entry
ports in the base and roof of the cabinet.
This allows for the feeder cable stub and up to 3
distribution stubs to enter the cabinet for splicing in to the
adjacent splice trays. All incoming and outgoing fibers are
routed through a fiber breakout protector. ThermalPro cabinets
have been tested to Telcordia GR 487 specifications and are
NEMA4 compliant.
|
|
 |
SPC's ThermalPro Fiber Optic 816 Series is Splitter Module
designed to receive up to 32 feeder fibers from the CO or main
fiber trunk line, split the signal and distribute it to a
maximum of 816 subscribers.
Built from heavy gauge aluminum with an aesthetic powder coat
finish, this cabinet can be expanded to serve growing fiber
optic needs. The left end bay is for cable entry, fiber
splicing, and connection to the backside of the distribution
patch panels. There are 4 sealed cable entry ports in the base
and roof of the cabinet.
The cabinet is equipped with 816 adapters installed in a central
divider panel, separating the splice chamber from the subscriber
connection side. Distribution fibers are routed to the splice
trays located in the splice tray rack. The outside plant feeder
and distribution cable can enter from either the bottom or the
top of the cabinet. ThermalPro cabinets have been tested to
Telcordia GR 487 specifications and are NEMA4 compliant |
|
 |
|
Designed and engineered to grow with ease, these aluminum
cabinets can be configured to meet any equipment requirements.
The modularity permits end users to specify the number of
equipment bays and utility end bays required.
All cabinets are built with standard 19”/23” equipment racks.
Select the number of equipment bays and the number of utility
end bays based on specific equipment space requirements: (EIA
1.75” spacing per U) The first digit of the model number
specifies the number of equipment bays, the second digit
specifies the number of utility end bays.
|

|
 |
|
Requirements for outdoor shelters are as varied as the
applications. Located in environments from building rooftops to
residential areas, these shelters can serve as wireless base
stations, transportation signaling systems, or network access
security for a host of energy, utilities, and communication
infrastructure.
These shelters are perfect for large DLC/DSL applications,
providing an economic alternative to multiple cabinets. SPC
offers shelters that are designed in modules, flexible for easy
assembly. Our paneled assemblies are constructed in three
layers, depending on materials selected, with the center layer
molded in polystyrene for advanced thermal management
capabilities at an attractive price.
This compound material can reduce by 30-50% the amount of
energy required for heating and cooling, creating a sizable
savings over the life of the enclosure. All cabinets are
designed to IP55 standards and are waterproof, fire resistant,
and offer the ultimate protection in harsh environments.
|
|
| |
 |
The SPC Access Cabinets are designed to serve numerous
applications: telecommunications, wireless, signaling,
transportation and CATV.
The compact size is ideally suited for locations where a small
and sophisticated enclosure is required. The cabinets come
equipped with pad lockable door and standard 19”/23” fixed
equipment rack. An optional swing out rack is available.
A wide selection of cabinet sizes and optional features combine
to provide exceptional flexibility to address a variety of
application uses. Select a standard size based on specific
equipment space requirements: (EIA 1.75” spacing per U) |

|
The GreenPro 42U cabinet comes in three models. Model 1 is
designed to house the power generation modules with controls;
Model 2 houses and secures the fuel tanks; and Model 3 is used to
contain both the fuel cell stacks and the fuel tanks in the same
cabinet.
For Model 3, the power generation compartment is separated from
the fuel storage compartment by an adjustable height compartment
barrier.
In addition, the modular design of the GreenPro allows for
multiple bay configurations. The bays are joined under a common
top cover to meet your space and capacity requirements. |
 |

Manufacturer's Information
Web Site:
www.spc.net
To order products, contact NuCore at (262) 970-7164 or email.
|
|
|
 |
|
|
|